On this page

Case Overview – Improving ESD Reliability in large size USB Display System

The exiting display system was upgraded from an older LVDS design to a new USB‑based architecture. During certification testing, the system passed the 8 kV contact discharge test but failed the 15 kV air discharge test. This caused video interruptions and system resets, preventing the product from being approved.

Our engineering team analyzed the issue and identified two main causes:

  1. The USB ground path had too much resistance during an ESD event.
  2. The USB power line did not have strong enough protection against voltage spikes.

After making targeted improvements, the system able to successfully pass the 15 kV air discharge test.

What Was Happening?

During testing, an ESD gun applies a high‑voltage static shock to the outside of the device. This simulates real‑world situations such as a user touching the screen after walking on carpet.

This shock caused the USB interface to momentarily fail, which led to:

  • Video freezing
  • Display blackouts
  • Touch panel communication loss
  • System resets

This happened because the USB interface is more sensitive to static electricity than the older LVDS design.

 

Root Cause Debug

  1. Grounding Was Too Weak for ESD

The USB ports used ferrite beads between the connector and ground. Ferrite beads are good for filtering noise, but they block fast, high‑energy ESD pulses. This prevented the static charge from safely going to ground.

  1. The USB Power Line Needed Better Protection

The USB 5 V line did not have a fast‑acting protection device to absorb sudden voltage spikes caused by ESD.

 

What We Changed

To fix the issue, we made three improvements:

✔ Direct Grounding

We removed the ferrite beads (L15 and L20) and connected the USB ground directly to the system ground.
This gives static electricity a clean, low‑resistance path to escape.

✔ Added TVS Protection

We added a high‑speed TVS diode (SP1326‑01LTG) to the USB 5 V line.
This device instantly clamps voltage spikes and protects the USB controller.

✔ Improved ESD Path

The new grounding and protection layout ensures that ESD energy is safely diverted away from sensitive components.

USB input schematic with ESD diodes, bead L15 and hand-drawn direct ground and added TVS on 5 V

Figure 1

 

USB output schematic with ESD diodes, bead L20 and hand-drawn direct ground and added TVS on 5 V

Figure 2

 

How the Improved Design Works

Before Fix

ESD Shock → Ferrite Bead → Blocked → USB Chip Overloaded → Video Failure

After Fix

ESD Shock → Direct Ground → TVS Clamp → USB Chip Protected → System Stable

Results

After applying these improvements:

  • The system passed 15 kV air discharge
  • No video dropouts or resets occurred
  • USB communication remained stable
  • The product is now ready for certification, BINGO!!

Conclusion

The ESD failures were caused by grounding impedance and insufficient surge protection in the USB interface. By optimizing the ground path and adding proper TVS protection, we restored the system’s reliability and ensured it meets certification requirements.

If you have any questions, please contact our engineering.

Frequently asked questions

Why did the USB display system fail the 15 kV air discharge ESD test?

It passed 8 kV contact discharge but failed 15 kV air discharge. Two causes were found: the USB ground path had too much resistance during an ESD event, and the USB 5 V line lacked strong protection against voltage spikes.

What symptoms does an ESD failure cause in a USB display system?

The ESD shock made the USB interface momentarily fail, causing video freezing, display blackouts, touch panel communication loss and system resets. The USB interface is more sensitive to static electricity than the older LVDS design.

Why are ferrite beads a problem on USB ground for ESD?

Ferrite beads are good for filtering noise, but they block fast, high-energy ESD pulses. With beads between the connector and ground, the static charge could not safely go to ground.

How was the ESD problem fixed?

The ferrite beads (L15 and L20) were removed and the USB ground was connected directly to system ground, giving ESD a low-resistance path. A high-speed TVS diode (SP1326-01LTG) was added to the USB 5 V line to clamp voltage spikes.

What was the result of the ESD fix?

The system passed the 15 kV air discharge test, with no video dropouts or resets and stable USB communication. The product is ready for certification.

New engineering articles by email.

Keep reading

Have a display project in mind?

Talk to an engineer about the display your application needs.